HTML automatically generated with rman
Table of Contents
mkking - initial conditions from a King model
mkking [parameter=value]
requires NEMO version 3.0.13 or higher, see http://www.astro.umd.edu/nemo.
mkking creates N-body initial conditions from an isotropic
single-mass Plummer model and writes them in NEMO snapshot format.
- out=file
- The initial conditions are written in NEMO snapshot format to
file. If file=-, output is made to stdout. Default: required.
- nbody=num
- The
initial conditions will contain num body masses, positions, and velocities.
Default: required.
- W0=val
- The dimensionless central potential depth of the
King model is set to val. Default: required.
- seed=num
- We will use num as
seed for the (pseudo-) random number generator. If num=0, a unique new seed
is created from the current value of the time, otherwise, the seed actually
provided is used. Default: 0.
- time=val
- The simulation time associated with
the initial conditions is set to val. Default: 0.
- mass=val
- The total mass
of the King model is set to val. Default: 1.
- r_c=val
- The core radius of the
King model is set to val. Default: 1.
- r_t=val
- If given, the limiting (or
truncation) radius of the King model is set to val and the core radius
given with the parameter r_c is ignored. No default.
- eps=val
- If given, a
softening length val is written out with each body. No default.
- q_ran=t|f
- If true, quasi-random rather than pseudo-random numbers are used. In this
case, the seed value becomes meaningless. Default: f.
- WD_units=t|f
- If true,
units for mass and r_c or r_t will be taken as solar mass and kpc, respectively,
but output units will be in kpc (positions), kpc/Gyr (velocities), and
222288.47 solar masses (implying Newton’s G=1). Default: f.
- outputs=t|f
- If
true, some global properties of the King model, like W0, total mass, core,
truncation & half-mass radius, central velocity dispersion and density, and
total energy are printed to stderr. Default: f.
- table=file
- If given, a table
with radii r, potential Phi(r), density rho(r), and cumulative mass M(r)
are written to file. No default.
mkdehnen(1falcON)
, mkplum(1falcON)
falcON/doc/user_guide.pdf User Guide for falcON
Walter Dehnen walter.dehnen@astro.le.ac.uk
update history of this man page
18-May-2004 first version of manual WD
Table of Contents